west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Central serous chorioretinopathy" 41 results
  • The differences of the choroidal thickness measured by spectral-domain optical coherence tomography in three kinds of imaging modes

    Objective o compare the differences in the choroidal thickness at 1500 μm nasal or temporal to the fovea between three measurements of different imaging modes. Methods In this retrospective study, 21 eyes from 20 patients diagnosed with central serous chorioretinopathy (CSC), whose retinas tilt over 5.0 degree to the horizontal line were included (retina tilt group). The control group (retinal horizontal group) also included 21 eyes from 20 individuals whose retinas are horizontal indicated by retinal tilt angle measurement. There were no statistical significance (t=0.00, -0.345, 0.489; P>0.05) in gender, age and spherical equivalent distributions between the two groups. The choroidal thickness at 1500 μm nasal or temporal to the fovea was measured by spectral-domain optical coherence tomography (COT) enhanced depth scanning under three modes (1∶1 pixel, 1∶1 micron and continuous measurement). The differences of choroidal thickness between these three measure modes were analyzed by a paired t test. Results The choroidal thickness was (304.81±87.74), (342.86±91.43), (307.86±89.35) μm respectively measured by 1∶1 pixel, 1∶1 micron and continuous measurement modes in retinal tilt group. The choroidal thickness measured by 1∶1 pixel was increased compare to that by 1∶1 micron, the difference was statistically significant (t=-8.499, P<0.01). The choroidal thickness measured by continuous measurement mode was the same of that by 1∶1 micron, the difference was not statistically significant (t=-0.790, P>0.05). In retinal horizontal group, the choroidal thickness measured by these 3 modes was the same, the difference was not statistically significant (t=-1.521, -1.822; P>0.05). Conclusions Spectralis OCT with 1∶1 pixel mode exhibits horizontally compressed image, the values of choroidal thickness under tilted retinas measured by this condition were significantly greater than the true ones. The choroidal thickness measured by 1∶1 micron mode measurement is more accurate. Continuous measurement mode provides more accurate and convenient choroidal thickness measurement during follow up of patients.

    Release date:2016-09-02 05:22 Export PDF Favorites Scan
  • Retrospective study of low-dose verteporfin photodynamic therapy for acute central serous chorioretinopathy

    ObjectiveTo evaluate the efficacy of 30% and 50% dose photodynamic therapy (PDT) for acute central serous chorioretinopathy (CSC). MethodsA retrospective cohort study. Ninety-two eyes of 88 patients with CSC, diagnosed by best corrected visual acuity (BCVA) of logarithm of the minimum angle of resolution (logMAR), indirect ophthalmoscope, fundus colorized photography, fundus fluorescein angiography (FFA), indocyanine green angiography (ICGA)and optical coherence tomography (SD-OCT) treated with 30% and 50% doses of verteporfin respectively between March 2007 and August 2013, were enrolled. The eyes were divided into 50% dose group (49 eyes) and 30% dose group (43 eyes). The differences of age (t=-1.45), gender (χ2=0.011), eyes (χ2=2.140), mean logMAR BCVA (t=-0.40), mean central retinal thickness (CRT) and the maximum thickness of serous retinal detachment (SRD) between two groups were not significant (P > 0.05). The difference of spot size between two groups was significant (t=-2.84, P < 0.05). The follow-up time was ranged from 6 to 68 months, with a mean of (17.16 ±11.30) months. The difference of follow-up between two groups was significant (P > 0.05). The BCVA, cure rate, recurrence rate and the changes of CRT and maximum SRT were observed by SD-OCT. ResultsThe subretinal fluid (SRF) of 31 eyes (72.09%) in the 30% dose group and that of 47 eyes (95.92%) in the 50% dose PDT group was absorbed completely respectively. The cure rates in the 30% dose PDT group was significantly less than that in the 50% dose group (χ2=10.077, P=0.020). There was a significant negative association between the cure rate and spot size by Logistic regression (odds ratio > 1, P=0.040). The difference of changes in the BCVA of logMAR in 50% dose group was better than that in 30% dose group after more than 12 months after PDT (P=0.036). On 3, 6, 12 and more than 12 months after PDT, the difference in CRT in 50% dose group and 30% dose group were not statistically significant (P=0.068, 0.060, 0.082, 0.067). The difference in maximum thickness of SRD was not statically significant (P > 0.05). SRF was appeared in 8 eyes (25.81%) of 31 eyes in the 30% dose group, while SRF was appeared in 1 eye (2.13%) of 47 eyes in the 50% dose group. The recurrence rate of 30% dose group was much higher than that of 50% dose group (P < 0.05). ConclusionsFor acute CSC treated by PDT, the curative effect of 50% dose group is better than the 30% dose group.

    Release date: Export PDF Favorites Scan
  • Retrospective study of 30% and 50% dose verteporfin photodynamic therapy versus anti-vascular endothelial growth factor for chronic central serous chorioretinopathy

    ObjectiveTo compare the efficacy among 30% and 50% dose of verteporfin photodynamic therapy (PDT) and intravitreal anti-vascular endothelial growth factor (anti-VEGF) in the treatment of chronic central serous chorioretinopathy (CSC). Methods138 eyes of 125 patients with chronic CSC, who were treated in our hospital from March 2006 to May 2014, were enrolled in this retrospective study. All patients were confirmed by spectral domain optical coherence tomography (SD-OCT) and best corrected visual acuity (BCVA), which was recorded with logMAR BCVA. And all the patients were divided into three groups by different treatments: 30% dose group (42 eyes of 39 patients); 50% dose group (77 eyes of 67 patients); anti-VEGF group (19 eyes of 19 patients). The differences of age, gender, eyes, courses, mean logMAR BCVA among three groups were not significant. Disappearing of fluid under retina in SD-OCT was considered to be cured and fluid remaining was not cured. If fluid appeared again the eyes were relapsed. We comparatively analyzed the cure rate, relapse rate and changing of BCVA, central macular thickness (CMT) among 3 groups of patients after 1, 3, 6 months. ResultsThe cure rate among 3 groups after 1 month was statistically different (χ2=6.926, P=0.031). The cure rates of 50% dose PDT treatment group after 3 months and 6 months were better than 30% dose PDT treatment group, but the differences were not significant (χ2=2.218, 1.682; P=0.136, 0.195). The relapse rate between 30% dose and 50% dose PDT treatment groups after 3 months and 6 months were not significant (χ2=2.133, 3.366; P=0.144, 0.067). The improvement of BCVA in 50% dose PDT treatment group was the best, but comparing with the other two groups, the differences were not significant in statistics (P > 0.05). The improvement of CMT in 50% dose PDT treatment group was the best. Comparing with anti-VEGF group, the differences was significant (P < 0.05). But comparing with 30% dose PDT treatment group, the differences was not significant (P > 0.05). Logistic regression analysis showed that after treatment, the cure rates after 1 month and 6 months were negatively correlated with the age (regression coefficient=-0.942, -0.979; odds ratio=0.390, 0.375; P < 0.05) and the cure rates after 3 months was positively correlated with the dose of verteporfin (regression coefficient=0.855, odds ratio=2.351, P < 0.05). Conclusion50% dose verteporfin PDT is recommend for chronic CSC treatment.

    Release date: Export PDF Favorites Scan
  • The efficacy of half-dose verteporfin photodynamic therapy for chronic central serous chorioretinopathy

    ObjectiveTo evaluate the efficacy and safety of half-dose verteporfin photodynamic therapy (PDT) for chronic central serous chorioretinopathy (CSC). Methods35 eyes (35 patients) with chronic (or recurrent) CSC treated with half-dose verteporfin PDT. Best-corrected visual acuity(BCVA), central macular thickness (CMT) were measured before and after treatment (1, 3 and 6 months). The mean BCVA was 0.28±0.22, mean CMT was(384.5±85.0)μm. The situation of subretinal fluids (SRF) absorption was observed. ResultsIn 35 eyes, SRF of 29 eyes (82.9%) completely absorbed and 6 eyes (17.1%) not completely absorbed after one month of treatment. SRF of all eyes (100.0%) completely absorbed after three months of treatment. After 6 months of treatment, SRF of 3 eyes (8.6%) were recurrence, which might be completely absorbed when a half-dose maintenance therapy PDT was used again. The mean BCVA significantly improved to 0.14±0.13 at 1 months, 0.05±0.11 at 3 months and 0.05±0.12 at 6 months after PDT (t=5.410, 7.830, 7.758; P < 0.05). The mean CMT decreased to (224.3±61.4) μm at 1 months, (199.6±32.7) μm at 3 months and (205.3±39.6) μm at 6 months after PDT (t=11.856, 11.781, 11.900; P < 0.05). The mean CMT of controlled 32 eyes after treatment was (198.5±33.9) μm, much lower than the fellow eyes(232.3±17.5) μm (t=-3.988, P < 0.05). ConclusionsHalf-dose verteporfin PDT was safe and effective in treating chronic CSC, but may cause thinning of CMT.

    Release date: Export PDF Favorites Scan
  • Strengthening multi-center randomized controlled trial to improve clinical research of ocular fundus diseases in China

    Multicenter randomized controlled studies can recruit more subjects in a relatively short period of time, avoiding the bias of single research institution studies, resulting in reliable conclusions and providing strong guidance to clinical practice. They are the most scientific and most reliable methods to evaluate clinical researches. However, there are few multicenter clinical trials in China as Chinese doctors are often trapped in difficulties in clinical research, including imperfect research system, lack of experience, capital investment deficient, the tension in the doctor-patient relationship and so on. Although the above problems are related to medical system architecture of our country in a certain extent, compared with the overseas, we also have our own advantages, such as resource of our patients, doctors, and diseases type. Pay attention to discovering of new type of diseases, looking for genetics discipline, and exploring new medical technology is an important task of clinical research. We have plenty of high level ophthalmology centers at present, which provide favorable conditions for launching multi-center clinical trial studies. We have good reasons to believe that, if we can effectively exploit the resources in our hands, carefully observe and discover clinical problems, there will be more convincing clinical results present in the world after bring up hypothesis boldly while prove it conscientiously and carefully.

    Release date: Export PDF Favorites Scan
  • The characteristics of blue light versus near infrared wavelength fundus autofluorescence in central serous chorioretinopathy patients

    ObjectiveTo observe the characteristics of blue light(BLAF) versus near infrared wavelength (IRAF) fundus autofluorescence in central serous chorioretinopathy (CSC) patients. MethodsSeventy-seven eyes of 81 patients diagnosed with CSC were enrolled in this study. According to the duration of disease, patients were divided into acute CSC group and chronic or recurrent CSC group. All patients were examined with fundus fluorescein angiography, including BLAF and IRAF. There were forty-six patients (47 eyes) with acute, thirty-one patients (34 eyes) with chronic or recurrent CSC. The characteristics of BLAF and IRAF in CSC were compared. ResultsIn acute CSC, there were nineteen eyes (40.4%) showed scattered hyper-fluorescence corresponding to the leaking points, eleven eyes (23.4%) showed mottled hypo-fluorescence in BLAF; while 17 eyes (36.2%) showed normal change corresponding to the leaking points. There were 35 eyes can be observed serous retinal detachments in the BLAF images, 21 eyes (60.0%) showed hypo-fluorescence and 14 eyes (40.0%) showed hyper-fluorescence. In the IRAF images, 25 eyes (53.2%) showed mottled fluorescence corresponding to the leaking points, 11 eyes (23.4%) presented with scattered hyper-fluorescent spots and normal fluorescence. The serous retinal detachments of 26 eyes exhibited hypo-fluorescence in the IRAF images. In chronic or recurrent CSC, 19 eyes (55.9%) showed scattered hyper-fluorescence corresponding to the leakage points; followed by no abnormal change in 10 eyes, accounting for 29.4%; few showed mottled hypo-fluorescence (5 eyes 14.7%). There were 35 eyes (41.2%) can be observed serous retinal detachments in the BLAF images. IRAF mainly displayed mottled hypo-fluorescence (22 eyes, 64.7%), ten eyes (29.4%) presented with scattered hyper-fluorescence and 2 eyes (5.8%) presented without abnormal change. The serous retinal detachments of 3 eyes (8.8%) exhibited hypo-fluorescence in the IRAF images. ConclusionsFor acute CSC, a variety of fluorescence were showed in BLAF images and the proportion of the various fluorescences was similar; hypo-fluorescence was showed in the IRAF images. For chronic CSC, hyper-fluorescence was showed in BLAF while hypo-fluorescence in the IRAF images.

    Release date: Export PDF Favorites Scan
  • Observation on imaging features of two types of fundus autofluorescence and spectral-domain optical coherence tomography in acute central serous chorioretinopathy

    ObjectiveTo observe the imaging features of short-wave length fundus autofluorescence (SW-AF), near-infrared fundus autofluorescence (NIR-AF)and spectral-domain optical coherence tomograph (SD-OCT) in acute central serous chorioretinopathy (CSC). MethodsThis is a retrospective observational consecutive case series study. Eighty-two eyes with acute CSC from 76 patients were enrolled in this study.There were 50 males (56 eyes) and 26 females (26 eyes), average age was (41.32±7.37) years old, average course of the disease was (0.47±1.73) months. The routine clinical examinations included best corrected visual acuity, slit lamp microscope, indirect ophthalmoscope, fundus fluorescein angiography (FFA), SW-AF, NIR-AF and SD-OCT. The imaging features of NIR-AF, SW-AF, SD-OCT and FFA in same eye with acute CSC were analyzed comparatively. ResultsSD-OCT showed retinal pigment epithelium (RPE) detachment corresponding to RPE leakage point on FFA images in all CSC eyes. RPE leakage points in all eyes corresponding to local hypo-NIR-AF, whereas corresponding to normal SW-AF. NIR-AF demonstrated the area of decreased AF corresponding to serous retinal detachment in all eyes, of which, the area of hypo-SW-AF was consistent with that of sensory retinal detachment in 75 eyes. Except for RPE leaking fluorescein in 82 eyes, FFA showed window defects corresponding to clusters of hypo-NIR-AF in 45 eyes, of which, 27 eyes showed hypo-SW-AF appearing concurrently with the locations of window defects of FFA. In 18 eyes, the extent and amount of hypo-SW-AF were less than that of hypo-NIR-AF. ConclusionsThere was local RPE detachment in all eyes with acute CSC. The locations of sensory retinal detachment, local RPE detachment and RPE depigmentation showed hypo-NIR-AF. The locations of sensory retinal detachment and RPE depigmentation showed hypo-SW-AF in most of acute CSC eyes.

    Release date: Export PDF Favorites Scan
  • Analysis of inner and outer retinal thickness after photodynamic therapy in chronic central serous chorioretinopathy

    ObjectiveTo observe the characteristic variation of the patients' inner and outer retina who had chronic central serous chorioretinopathy (CSC) after being treated of photodynamic therapy (PDT). MethodsNineteen patients with chronic CSC were recruited, including 15 eye of men and 4 eye of women, logMAR BCVA was 0.1-1.0, 0.39±0.30. Meanwhile, 24 healthy people were located in the control group. All the patients received PDT for the first time. All subjects including 24 healthy people underwent fourier domain optical coherence tomography (FD-OCT). Retinal thickness were investigated before PDT and 1, 4, 12, 20 weeks after PDT respectively. Data were recorded including inner layer and outer layer. Retinal thickness were compared in fovea (1 mm), parafovea (3 mm)and perifovea(5 mm). Paired-samples t test was used to compare retinal thickness before and after PDT. The statistical differences of patients and control group were evaluated by independent-samples t test. The correlations between the best logMAR corrected visual acuity (BCVA) was analyzed by Pearson statistical analyses. ResultsThe inner(F=13.814, 10.095, 4.689) and outer(F=9.354, 5.878, 3.978)layer fovea thickness of CSC subjects in 1, 4, 12 week was thinner, the difference was statistically significant (P < 0.05). The outer layer fovea thickness at P12(t=-3.725), parafovea of inner and outer retinal(t=-3.198, -2.722)was reduced when compared with control group, and differences have statistical sense, respectively (P < 0.05). There was correlation between logMAR BCVA and outer retinal thickness in fovea and parafovea (r=0.465, -0.728, -0.687; P < 0.05). ConclusionIn our study, the inner and outer layer retinal thickness decreased generally after the first time PDT in CSC patients.

    Release date: Export PDF Favorites Scan
  • Micro-pulse laser therapy for acute central serous chorioretinopathy

    ObjectiveTo observe the effect of micro-pulse laser in the treatment of acute central serous chorioretinopathy (CSC). Methods105 cases (114 eyes) with clinically diagnosed acute CSC were included in the study, including 78 males (86 eyes) and 27 females (28 eyes) with an average age of (40.40±7.80) years, and mean duration of 26 days. All patients were examined for best corrected visual acuity (BCVA), slit lamp microscope and pre-lens, direct ophthalmoscopy, color fundus photography, fluorescein angiography combined with indocyanine green angiography (ICGA), and micro-perimetry. Patients were randomly divided into micro-pulse laser treatment group (treatment group, 61 eyes) and control group (51 eyes). The age (Z=-0.374), gender ratio (χ2=0.010), disease duration (Z=-0.525), BCVA (t=1.885), foveal thickness (CFT) (t=-1.754) and macular light sensitivity (t=1.255) were similar between the two groups. The micro-pluse laser treatment was performed with an 810 nm infrared diode laser at the active leakage site on retinal pigment epithelium guided by ICGA. The exposure time was 0.2 s, effective working time was 15%, the laser spot diameter was 100 μm, and the distance between 2 spots was 100 μm. The control group received pseudo-treatment using the same laser parameters. After 2 weeks, 1month, 3 months and 6 months of treatment, all patients were examined with BCVA, ocular fundus, optical coherence tomography and micro-perimetry. These parameters were compared between the 2 groups. ResultsThe subretinal fluid of 39 eyes in the micro-pulse laser group and that of 3 eyes in the control group were absorbed completely. The cure rates in the micro-pulse laser group(61.9%) was higher than that in the control group (χ2=38.015, P < 0.01). In the micro-pulse laser group, the mean BCVA was 67.81±11.70 at baseline, which increased significantly to 75±9.91, 76.78±9.43, 78.56±8.57 and 78.52±8.60 at 2 weeks, 1 month, 3 months and 6 months after treatment respectively. In the control group, that was 63.86±10.35, 64.20±11.43, 63.90±10.88, 64.55±11.04, 64.10±11.12 at baseline, 2 weeks, 1 month, 3 months, 6 months post-treatment respectively. The mean post-treatment BCVA at each time point were significantly higher in the micro-pulse laser group than that in the control group(P < 0.01). The mean CFT was(380.94±50.73) μm at baseline, which reduced to(268.44±44.20), (242.78±41.31), (235.46±38.44), (235.56±38.71) μm at 2 weeks, 1 month, 3 months and 6 months post-treatment respectively in the micro-pulse laser group. In the control group, that was (397.98±52.61), (334.55±59.15), (316.16±55.25), (314.47±53.27), (321.51±55.74) μm at baseline, 2 weeks, 1 month, 3 months, 6 months post-treatment respectively. The mean post-treatment CFT at each time point in the micro-pulse laser group were decreased significantly compared to that in the control group (P < 0.01). The mean central retinal sensitivity was (15.03±2.00) dB at baseline, which enhanced to (17.06±1.71), (17.37±1.61), (17.56±1.58), (17.48±1.53) dB at 2 weeks, 1 month, 3 months and 6 months post-treatment respectively in the micro-pulse laser group. In the control group, that was (14.54±2.22), (14.80±2.16), (14.88±2.09), (14.82±2.07), (14.69±2.11) dB at baseline, 2 weeks, 1 month, 3 months and 6 months post-treatment respectively. The mean central retinal sensitivity at each time point of post-treatment in the micro-pulse laser group were enhanced significantly compared to that in the controlled group(P < 0.01). ConclusionIn the treatment of acute CSC, micro-pulse laser can improve BCVA, reduce the mean CFT and improve the mean central retinal sensitivity. It is an effective and safe method to treat acute CSC.

    Release date: Export PDF Favorites Scan
  • Optical coherence tomography characteristics and their relationship with vision prognosis in central serous chorioretinopathy patients with different symptom duration before and after photodynamic therapy

    ObjectiveTo observe the characteristics of optical coherence tomography (OCT) in central serous chorioretinopathy (CSC) patients with different symptom duration before and after photodynamic therapy (PDT), and investigate its relationship with vision prognosis. Methods93 CSC patients (103 eyes) who had undergone the treatment of PDT were enrolled in this study. The eyes were divided into 3 groups according to symptom duration including group A (< 4 months, 28 eyes), group B (4-6 months, 42 eyes), group C (> 6 months, 33 eyes). The best corrected visual acuity (BCVA) and OCT were performed before and after treatment. Before the treatment, the percentage of patients with regular retinal pigment epithelium (RPE), irregular bump or detachment of RPE and disordered RPE were 63.0%, 37.0%, 0.0% in group A; 41.9%, 53.5%, 4.7% in group B and 24.2%, 57.6%, 18.2% in group C, respectively. The difference of percentage of RPE structure was no significance among the three groups (χ2=19.88, P=0.001). The outer nuclear layer (ONL) thickness was (220.42±49.88), (145.81±19.65), (98.15±33.02) μm in group A, B, C respectively, the difference between three groups was significant (P=0.000). The BCVA differences in different RPE structure and the relationship between ONL thickness and vision prognosis were recorded and analyzed. ResultsThe difference of ONL thickness in eyes with regular RPE and irregular bump or detachment of RPE in group A, B and C were not significant (P=0.599, 0.151, 0.789). The ONL thickness in eyes with disordered RPE were decreased significantly compared to eyes with irregular bump or detachment of RPE in group B and C (P=0.025, 0.036). The ONL thickness were (139.14±26.23), (119.14±21.09), (97.61±29.92) μm after PDT, respectively. Compared with ONL thickness before PDT, there was statistically significant decreasing after PDT in group A and B (P=0.000, 0.010), but there was no statistically significant difference after PDT in group C (P=0.192). After PDT, BCVA was negatively related to ONL thickness before PDT in group A (r=-0.684, P=0.000), and was positively related to ONL thickness after PDT in group C (r=0.413, P=0.017), but was neither related to ONL thickness before nor after PDT in group C (r=0.278, 0.117; P=0.074, 0.462). ConclusionsWith the duration of symptom being longer, the rate of irregular bump or detachment of RPE and disordered RPE are increased gradually, ONL thickness is getting thinner. After PDT, the ONL thickness became thinner in eyes with symptom duration less than 6 months and has no difference in eyes with symptom duration more than 6 months. The difference of BCVA in eyes with different RPE structure is significant. The vision prognosis of CSC with duration less than 4 months or more than 6 months are related to ONL thickness.

    Release date: Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content